3 PART 3 SUMMARY 3.1 Tests When using glass in a proprietary walling system, a certificate shall be obtained from the manufacturer confirming testing for water/air pressure by a recognized testing authority, to relevant standards approved in advance by the Engineer, at which the Engineer shall be expected to attend. The Engineer may also or alternatively require a full mock up test of proposed walling to check water permeability and air tightness and/or other properties. 3.2 Reference Documents 3.2.1 Standards Reference Title ASTM C1048 Standard Specification for Heat-Treated Flat Glass–Kind HS, Kind FT Coated and Uncoated Glass Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds Fire tests on building materials and structures. Method for determination of the fire resistance of elements of construction (general principles) Fire tests on building materials and structures. Methods for determination of the fire resistance of loadbearing elements of construction Fire tests on building materials and structures. Methods for determination of the fire resistance of non-loadbearing elements of construction Fire tests on building materials and structures. Methods for determination of the contribution of components to the fire resistance of a structure Timber windows. Factory assembled windows of various types. Specification Glass for glazing. Classification Glass for glazing. Terminology for work on glass Methods of test for resistance to air and water penetration. Permeable walling constructions (water penetration) Specification for anti-bandit glazing (glazing resistant to manual attack) Specification for hermetically sealed flat double glazing units Specification for impact performance requirements for flat safety glass and safety plastics for use in buildings Performance of windows and doors Steel-framed windows and glazed doors Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-u) extruded hollow profiles Workmanship on building sites. Code of practice for glazing Glass in building. Security glazing. Testing and classification of resistance against manual attack Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance Glass in building. Determination of luminous and solar characteristics of glazing Unplasticized polyvinylchloride (PVC-u) profiles for the fabrication of windows and doors. Determination of the strength of welded corners and T-joints Windows and doors. Air permeability. Test method Glass in building. Security glazing. Testing and classification of resistance against bullet attack Steels for quenching and tempering Unplasticized polyvinylchloride (PVC-u) profiles for the fabrication of windows and doors. Classification, requirements and test methods Glass in building. Heat-soaked thermally-toughened soda lime silicate safety glass. Definition and description Glass in building. Heat-soaked thermally-toughened soda lime silicate ASTM D2287 BS 476: Part 20 BS 476: Part 21 BS 476: Part 22 BS 476: Part 23 BS 644 BS 952: Part 1 BS 952: Part 2 BS 4315: Part 2 BS 5544 BS 5713 BS 6206 BS 6375 BS 6510 BS 7412 BS 8000: Part 7 BS EN 356 BS EN 357 BS EN 410 BS EN 514 BS EN 1026 BS EN 1063 BS EN 10083 BS EN 12608 BS EN 14179: Part 1 BS EN 14179: Part 2 Page 11